resident:leahthan_domeshek
Differences
This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
| resident:leahthan_domeshek [2021/07/08 10:12] – [Breast Reduction] taylor | resident:leahthan_domeshek [2021/07/12 09:41] (current) – taylor | ||
|---|---|---|---|
| Line 10: | Line 10: | ||
| [[https:// | [[https:// | ||
| - | |||
| - | ===== Operative Reports ===== | ||
| General Tips:\\ | General Tips:\\ | ||
| \\ | \\ | ||
| + | ===== Operative Reports ===== | ||
| + | |||
| + | ==== Breast Reduction ==== | ||
| + | |||
| + | <WRAP Group> | ||
| + | <WRAP half column> | ||
| + | |||
| + | The patient was marked preoperatively in the holding area in an upright standing position. Sternal notch was marked, followed by bilateral breast meridians and IMFs and chest midline. New nipple position was determined by transposition of the IMF onto the meridian of each breast. New notch to nipple distances were 21 cm bilaterally. XX cm limbs were designed emanating obliquely inferiorly from this point to create 2 limbs of an equilateral triangle and indicate what would become the vertical closure. These limbs were connected to the medial and lateral extents of the IMF markings. | ||
| + | |||
| + | Once the markings were in place, the patient was brought to the operating room and positioned supine on the operating room table, | ||
| + | |||
| + | A surgical timeout confirming patient and procedure was performed. The patient' | ||
| + | |||
| + | Preoperative markings were confirmed on the table. A 38mm cookie cutter was used to mark the new NAC, placed on bilateral breasts with the same applied pressure. An inferior pedicle technique was to be utilized and the expected pedicles were marked on the skin, using an 8cm base centered on the midline of each breast. | ||
| + | |||
| + | A near identical surgical procedure was then performed on both breasts: | ||
| + | |||
| + | A lap sponge was placed around the base of the breast to create a tourniquet effect. Incision was made through epidermis and into but not through dermis around each pedicle and nipple-areola complex. The pedicles were then de-epithelialized using a 10 blade. Incision was then made through skin into subcutaneous tissues along all remaining surgical markings. The pedicle was then defined using electrocautery: | ||
| + | The intervening tissues between the pedicle and elevated skin flaps were resected using cautery. All resected tissues were saved and sent to Pathology for routine histologic examination. Careful attention was paid to hemostasis throughout the procedure. | ||
| + | |||
| + | On multiple occasions, the patient was sat in an upright sitting position to assess for size, shape, and symmetry of the breasts. | ||
| + | |||
| + | The patient was returned to the supine position, and copious irrigation was performed and hemostasis confirmed. A 15 Fr round blake drain was placed in each breast, exiting inferolateral to the IMF incision. | ||
| + | |||
| + | The breast skin was then stapled into anticipated closure pattern and the designed NAC region on each breast was excised using a scalpel. The nipple was then delivered through this created defect and sutured in place with 4-0 monocryl deep dermal stitches. | ||
| + | |||
| + | A layered closure of both breasts was performed consisting of interrupted 3-0 Monocryl buried deep dermal sutures followed by a running 4-0 Monocryl subcuticular suture along the IMF incision as well as the vertical closure limb. Around the NAC, closure consisted of 4-0 Monocryl deep dermal sutures followed by a running subcuticular 5-0 Monocryl stitch. | ||
| + | |||
| + | The closures were covered by Prineo tape. | ||
| + | |||
| + | The patient tolerated this procedure without complication, | ||
| + | |||
| + | </ | ||
| + | <WRAP half column> | ||
| + | |||
| + | Drain: Case-dependent\\ | ||
| + | Sutures: 3-0 monocryl, 4-0 monocryl for incisions; 4-0 (deep dermal) and 5-0 (subcuticular) monocryl for nipple; 4-0 nylon for drain stitch if applicable; 3-0 fast for rescue stitches\\ | ||
| + | Dressing: Prineo/ | ||
| + | |||
| + | </ | ||
| + | </ | ||
| + | |||
| + | ====Ganglion Cyst Excision==== | ||
| + | <WRAP Group> | ||
| + | <WRAP half column> | ||
| + | |||
| + | The patient was brought back to the operating room and placed supine on the operating room table. After successful induction of anesthesia, a surgical timeout confirming patient and procedure was performed. | ||
| + | |||
| + | A nonsterile tourniquet was placed high up on the right arm and the arm was placed on a hand table. | ||
| + | |||
| + | The extremity was exsanguinated with the use of an esmarch and the tourniquet was inflated to 250 mmHg. Incision was made along the surgical marking into the subcutaneous tissue using a #15C blade. Once in the subcutaneous tissue, blunt dissection commenced using iris scissors and tenotomies. Once dissection had proceeded down to the surface of the cyst, blunt dissection was used to circumferentially free the lesion from surrounding tissue from attachments. | ||
| + | |||
| + | On its deep surface, the cyst was adherent to a small portion of the A2 pulley. | ||
| + | |||
| + | Hemostasis was confirmed, the site irrigated again, and then skin was closed with a combination of 4-0 Nylon horizontal mattress and simple interrupted stitches. | ||
| + | |||
| + | The site was dressed with ointment, adaptic, telfa, 4x4s, kling, webril, and a volar resting splint allowing flexion of digits distal to the MCPJ. | ||
| + | |||
| + | The patient tolerated all of this well and awoke from anesthesia without difficulty. The patient was brought in stable condition to the PACU. | ||
| + | |||
| + | </ | ||
| + | <WRAP half column> | ||
| + | |||
| + | Tourniquet: 100mmHg over patients SBP. She puts tape around the distal border of the tourniquet/ | ||
| + | Sutures: 4-0 nylon horizontal mattress\\ | ||
| + | Dressing: Bacitracin ointment to incision, Adaptic, Telfa, 4x4s, kling wrap, webril, volar/ | ||
| + | |||
| + | </ | ||
| + | </ | ||
| + | |||
| + | ==== Lip Laceration ==== | ||
| + | She prefers 3-0 or 4-0 vicryl for the orbicularis muscle. This was a lip washout and then 4-0 or 5-0 preferred chromic for the wet part of the lip and 5-0 plain got for the dry part of the lip put a little Vaseline on that and make sure you do a very thorough wash out. | ||
| ===== Nerve Transfers ===== | ===== Nerve Transfers ===== | ||
| Line 80: | Line 150: | ||
| - | ===== Lip Laceration ==== | + | ====Triceps to Axillary Nerve Transfer==== |
| - | She prefers 3-0 or 4-0 vicryl for the orbicularis muscle. This was a lip washout and then 4-0 or 5-0 preferred chromic for the wet part of the lip and 5-0 plain got for the dry part of the lip put a little Vaseline on that and make sure you do a very thorough wash out. | + | |
| - | + | ||
| - | =====Triceps to Axillary Nerve Transfer===== | + | |
| <WRAP Group> | <WRAP Group> | ||
| Line 112: | Line 179: | ||
| </ | </ | ||
| </ | </ | ||
| - | |||
| - | ==== Breast Reduction ==== | ||
| - | |||
| - | The patient was marked preoperatively in the holding area in an upright standing position. Sternal notch was marked, followed by bilateral breast meridians and IMFs and chest midline. New nipple position was determined by transposition of the IMF onto the meridian of each breast. New notch to nipple distances were 21 cm bilaterally. XX cm limbs were designed emanating obliquely inferiorly from this point to create 2 limbs of an equilateral triangle and indicate what would become the vertical closure. These limbs were connected to the medial and lateral extents of the IMF markings. | ||
| - | |||
| - | Once the markings were in place, the patient was brought to the operating room and positioned supine on the operating room table, | ||
| - | |||
| - | A surgical timeout confirming patient and procedure was performed. The patient' | ||
| - | |||
| - | Preoperative markings were confirmed on the table. A 38mm cookie cutter was used to mark the new NAC, placed on bilateral breasts with the same applied pressure. An inferior pedicle technique was to be utilized and the expected pedicles were marked on the skin, using an 8cm base centered on the midline of each breast. | ||
| - | |||
| - | A near identical surgical procedure was then performed on both breasts: | ||
| - | |||
| - | A lap sponge was placed around the base of the breast to create a tourniquet effect. Incision was made through epidermis and into but not through dermis around each pedicle and nipple-areola complex. The pedicles were then de-epithelialized using a 10 blade. Incision was then made through skin into subcutaneous tissues along all remaining surgical markings. The pedicle was then defined using electrocautery: | ||
| - | The intervening tissues between the pedicle and elevated skin flaps were resected using cautery. All resected tissues were saved and sent to Pathology for routine histologic examination. Careful attention was paid to hemostasis throughout the procedure. | ||
| - | |||
| - | On multiple occasions, the patient was sat in an upright sitting position to assess for size, shape, and symmetry of the breasts. | ||
| - | |||
| - | The patient was returned to the supine position, and copious irrigation was performed and hemostasis confirmed. A 15 Fr round blake drain was placed in each breast, exiting inferolateral to the IMF incision. | ||
| - | |||
| - | The breast skin was then stapled into anticipated closure pattern and the designed NAC region on each breast was excised using a scalpel. The nipple was then delivered through this created defect and sutured in place with 4-0 monocryl deep dermal stitches. | ||
| - | |||
| - | A layered closure of both breasts was performed consisting of interrupted 3-0 Monocryl buried deep dermal sutures followed by a running 4-0 Monocryl subcuticular suture along the IMF incision as well as the vertical closure limb. Around the NAC, closure consisted of 4-0 Monocryl deep dermal sutures followed by a running subcuticular 5-0 Monocryl stitch. | ||
| - | |||
| - | The closures were covered by Prineo tape. | ||
| - | |||
| - | The patient tolerated this procedure without complication, | ||
| - | |||
| - | </ | ||
| - | <WRAP half column> | ||
| - | |||
| - | Drain: Case-dependent\\ | ||
| - | Sutures: 3-0 monocryl, 4-0 monocryl for incisions; 4-0 (deep dermal) and 5-0 (subcuticular) monocryl for nipple; 4-0 nylon for drain stitch if applicable; 3-0 fast for rescue stitches\\ | ||
| - | Dressing: Prineo/ | ||
| - | |||
| - | </ | ||
| - | </ | ||
| - | |||
resident/leahthan_domeshek.1625753574.txt.gz · Last modified: 2021/07/08 10:12 by taylor
