resident:michael_gordon
Differences
This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
| resident:michael_gordon [2021/08/02 19:48] – [Scapholunate Repair] jonathan | resident:michael_gordon [2022/12/23 13:52] (current) – [Panniculectomy] haley.d | ||
|---|---|---|---|
| Line 49: | Line 49: | ||
| 3. blue towel wrapped around arm help by penetrating towel clamp\\ | 3. blue towel wrapped around arm help by penetrating towel clamp\\ | ||
| 4. long sheet over patient - held in place by 4 non penetrating towel clamps\\ | 4. long sheet over patient - held in place by 4 non penetrating towel clamps\\ | ||
| + | ====Trigger Finger==== | ||
| + | |||
| + | <WRAP Group> | ||
| + | <WRAP half column> | ||
| + | |||
| + | Operative Report:\\ | ||
| + | |||
| + | Indication: This is a 69 year old male who previously presented to clinic with trigger fingers of the right long and ring fingers that was severe and caused the patient significant discomfort. Excision of A1 pulleys of the ring and long fingers was recommended. The risks of the procedure including pain, bleeding, infection, wound healing complications, | ||
| + | Report: | ||
| + | The patient was marked in the pre-operative area, and then brought to OR #4. A timeout was performed, and the patient was placed under sedation anesthesia. Lidocaine was locally infiltrated into the surgical site, and the patient was prepped and draped in sterile fashion. | ||
| + | A second timeout was performed confirming correct patient and surgical site, and the patient’s extremity was exsanguinated and tourniquet inflated to 250mmHg. First attention was turned to the ring finger. A longitudinal incision was made over the palmar aspect of the metacarpal head, directly over the A1 pulley. Litler scissors were used to carefully dissect down to the flexor tendon. The proximal end of the A1 pulley was identified and incised ulnarly and radially using Litlers to fully excise the A1 pulley and the proximal portion of A2. This was passed off the table. The finger was ranged and demonstrated no further triggering. | ||
| + | Next, attention was turned to the long finger. A longitudinal incision was made over the palmar aspect of the metacarpal head, directly over the A1 pulley. Litler scissors were used to carefully dissect down to the flexor tendon. The proximal end of the A1 pulley was identified and incised ulnarly and radially using Litlers to fully excise the A1 pulley and the proximal portion of A2. The pulley was examined and appeared thickened. The underlying tendon demonstrated moderate fraying. The pulley was passed off the table, and the finger was ranged. The long finger did not stick, but demonstrated stiffer joint motion. Finally, both incisions were closed with 5-0 Nylon and dressed with Xeroform, wet gauze, dry gauze, Kerlix bandage, and an Ace wrap. All final instrument and sponge counts were correct. | ||
| + | |||
| + | Tourniquet Time: 36 minutes | ||
| + | |||
| + | Dr. Gordon was scrubbed in for the entirety of this procedure. \\ | ||
| + | |||
| + | </ | ||
| + | </ | ||
| + | |||
| ====Carpal Tunnel Release==== | ====Carpal Tunnel Release==== | ||
| Line 74: | Line 94: | ||
| Technical Steps:\\ | Technical Steps:\\ | ||
| -He will mark the incision.\\ | -He will mark the incision.\\ | ||
| - | -Uses Knife to cut until fat is seen, 2 ski hooks\\ | + | -Uses Knife to cut until fat is seen, 2 skin hooks\\ |
| -Bovie and smooth pickup to buzz vessels\\ | -Bovie and smooth pickup to buzz vessels\\ | ||
| -then he uses ragnels and sens and you use litler scissors to dissect down to transverse carpal ligament.\\ | -then he uses ragnels and sens and you use litler scissors to dissect down to transverse carpal ligament.\\ | ||
| Line 118: | Line 138: | ||
| 1. Right trapeziectomy with ligamentous reconstruction.\\ | 1. Right trapeziectomy with ligamentous reconstruction.\\ | ||
| - | After instillation of a supraclavicular block, the patient | + | After instillation of a supraclavicular block in the pre-operative area, the patient |
| + | Preoperative skin markings were designed as a 3 cm oblique incision along the dorsal radial aspect of the base of the 1st metacarpal. The hand and arm were then exsanguinated with the Ace wrap and finger tourniquet, and the tourniquet on the upper arm was inflated to 250 mmHg. The thumb was placed on 10 pounds of traction using a finger trap. Next, a scalpel | ||
| + | Next, the FCR tendon could be seen in the base of the wound, and the FCR tendon was sharply | ||
| </ | </ | ||
| Line 128: | Line 150: | ||
| **DOES NOT USE C-ARM** | **DOES NOT USE C-ARM** | ||
| - | Tourniquet: finger / forearm / arm\\ | + | Pre-operative block: Supraclavicular\\ |
| - | Drain: Type of drain and placement\\ | + | Tourniquet: upper arm, sterile\\ |
| Sutures: List all layers\\ | Sutures: List all layers\\ | ||
| Dressing: What's preferred? | Dressing: What's preferred? | ||
| - | Anatomy: | + | Anatomy: |
| Post-operative care: Include restrictions, | Post-operative care: Include restrictions, | ||
| - | Learning points/Pimp Questions: | + | Learning points/Pimp Questions: |
| + | * Will ask you to identify the articulations. The big saddle joint articulates with the metacarpal. Note the articulation with the second metacarpal as well. The others are of course the articulations with the trapezoid and the scaphoid.\\ | ||
| Special equipment: Bone anchor\\ | Special equipment: Bone anchor\\ | ||
| Sutures: 2-0 fiber wire for tendon reconstruction, | Sutures: 2-0 fiber wire for tendon reconstruction, | ||
| Notes: Removes trapezium whole. (ie. does not use rongeur unless a piece breaks)\\ | Notes: Removes trapezium whole. (ie. does not use rongeur unless a piece breaks)\\ | ||
| - | Will ask you to identify the articulations. The big saddle joint articulates with the metacarpal. Note the articulation with the second metacarpal as well. The others are of course the articulations with the trapezoid and the scaphoid.\\ | ||
| Sends trapezium for gross only pathology.\\ | Sends trapezium for gross only pathology.\\ | ||
| {{url> | {{url> | ||
| Line 689: | Line 712: | ||
| </ | </ | ||
| </ | </ | ||
| + | |||
| + | ====Breast Reduction==== | ||
| + | |||
| + | <WRAP group> | ||
| + | <WRAP half column> | ||
| + | |||
| + | Operative Report:\\ | ||
| + | 1. Reduction Mammaplasty\\ | ||
| + | \\ | ||
| + | The patient was taken to the operating room, and positioned on the surgical table. After a timeout confirming the correct patient and surgical procedure was conducted, general anesthesia was started. The patient was prepped and draped in standard fashion. \\ | ||
| + | |||
| + | A 38 mm cookie cutter was used to mark out the nipple areola complexes bilaterally. Next an approximately 10cm wide inferior pedicle on both breasts was marked and de-epithelialized using a knife. | ||
| + | |||
| + | At this point, the new NAC location was marked 6cm above the inferior incision with the 38mm cookie cutter bilaterally. This area of skin was removed using scissors and hemostased with electrocautery. The NAC was then inset with 5-0 Vicryl and 5-0 Fast-absorbing gut. The incisions were then dressed with Benzoin, steri-strips, | ||
| + | |||
| + | All final sponge and instrument counts were correct. The patient was extubated, placed in a surgical bra, and transferred to recovery without issue. \\ | ||
| + | |||
| + | Dr. Gordon was present for the entirety of this procedure. \\ | ||
| + | </ | ||
| + | |||
| + | <WRAP half column> | ||
| + | |||
| + | Photos\\ | ||
| + | |||
| + | Tourniquet: finger / forearm / arm\\ | ||
| + | Drain: Two 15-French Blake drains\\ | ||
| + | Sutures: 2-0 Vicryl, 4-0 Mono, 3-0 PDS, 5-0 Vicryl, 5-0 fast-gut\\ | ||
| + | Dressing: | ||
| + | |||
| + | Anatomy: Pertinent anatomy should be listed\\ | ||
| + | |||
| + | Post-operative care: Include restrictions, | ||
| + | |||
| + | Learning points/Pimp Questions: | ||
| + | |||
| + | </ | ||
| + | </ | ||
| + | |||
| + | |||
| ==== Lipoma Resection ==== | ==== Lipoma Resection ==== | ||
resident/michael_gordon.1627948103.txt.gz · Last modified: 2021/08/02 19:48 by jonathan